CRITICALAlarm code
741
ILLEGAL THREAD ANGLE (WNo., UNo., SNo.)
What it means
In the machining type that requires the designation of a threading angle, the following condition is not satisfied. (Tool tip angle) ≤ (Threading angle)
What to do
- 1Change either the threading angle or the data of the tool to be used.
Codebook — decoded
BError typeRegistered Data — program or tool data error
I (L)Stop statusunspecified
O (S)Clearingunspecified
Still faulted after these steps? Do not restart under load — ask the Mazatrol assistant.