NOTICEAlarm code
752
DESIGNATED AREA DATA IMPOSSIBLE (WNo., UNo., SNo.)
What it means
The check surface values are incorrect. 1. For rough-machining 1 or 2: Check surface Z min. ≥ material height 2. For finishing: Check surface Z min. > initial Z 3. Check surface X min. > X max., or Y min. > Y max., or Z min. > Z max.
What to do
- 1Set the check surface values as follows: 1.
- 2For rough-machining 1 or 2: Check surface Z min. < material height 2.
- 3For finishing: Check surface Z min. ≤ initial Z 3.
- 4Check surface X min. ≤ X max., and Y min. ≤ Y max., and Z min. ≤ Z max.
Codebook — decoded
BError typeRegistered Data — program or tool data error
I (L)Stop statusunspecified
O (S)Clearingunspecified
Still faulted after these steps? Do not restart under load — ask the Mazatrol assistant.