CRITICALAlarm code
771
ILLEGAL LOW TUR COMMON UNIT (WNo., UNo., SNo.)
What it means
A unit of machining with the lower turret (or including a command for its retraction) is created within a program whose common unit declares (under LOW TURR) that the lower turret is “not used”.
What to do
- 1Change over the LOW TURR setting, or modify the machining unit concerned in the turret selection.
Codebook — decoded
BError typeRegistered Data — program or tool data error
I (L)Stop statusunspecified
O (S)Clearingunspecified