CRITICALAlarm code
771

ILLEGAL LOW TUR COMMON UNIT (WNo., UNo., SNo.)

What it means

A unit of machining with the lower turret (or including a command for its retraction) is created within a program whose common unit declares (under LOW TURR) that the lower turret is “not used”.

What to do
  1. 1Change over the LOW TURR setting, or modify the machining unit concerned in the turret selection.
Codebook — decoded
BError typeRegistered Data — program or tool data error
I (L)Stop statusunspecified
O (S)Clearingunspecified
Still faulted after these steps? Do not restart under load — ask the Mazatrol assistant.