CRITICALAlarm code
810

PROGRAM END NOT FOUND (WNo., NNo., BNo.)

What it means

“EOR” has been detected during tape or memory operation.

What to do
  1. 1For the main program, set M02 or M30 at the end of the program.
  2. 2For subprograms, set M99 at the end of the program.
Codebook — decoded
BError typeRegistered Data — program or tool data error
I (L)Stop statusunspecified
O (S)Clearingunspecified
Still faulted after these steps? Do not restart under load — ask the Mazatrol assistant.