CRITICALAlarm code
810
PROGRAM END NOT FOUND (WNo., NNo., BNo.)
What it means
“EOR” has been detected during tape or memory operation.
What to do
- 1For the main program, set M02 or M30 at the end of the program.
- 2For subprograms, set M99 at the end of the program.
Codebook — decoded
BError typeRegistered Data — program or tool data error
I (L)Stop statusunspecified
O (S)Clearingunspecified
Still faulted after these steps? Do not restart under load — ask the Mazatrol assistant.