CRITICALAlarm code
887
TAPE I/O ERROR (WNo., NNo., BNo.)
What it means
1. An error occurred at the tape reader, or on the printer during macro printing. 2. Calling of a program inside the host computer failed during Ethernet operation. 3. The size of the output text file exceeded the value set for DPR8. When the cause is either No. 1 or 2 above, WNo., UNo. and BNo. will be displayed in the parentheses. When the cause is No. 3 above, the error type, detailed error code and “0” will be displayed in the parentheses. Error types 110: File open error, 111: File write error, 112: File size over error
What to do
- 11.
- 2Check the parameter.
- 32.
- 4Check the network connection between the NC and the host computer that stores the specified program.
- 53.
- 6Take actions below.
- 7Change the file size setting at parameter DPR8 to a value larger than the text file.
- 8Reduce the size of the text file to be output to within the file size setting at parameter DPR8.
- 9If a value other than “0” is displayed for the detailed error code in the parentheses, note the number and contact the nearest Mazak Technical Center or Technology Center.
Codebook — decoded
B (G)Error typeunspecified
IStop statusReset stop — waiting for reset
OClearingFix cause → press RESET
Still faulted after these steps? Do not restart under load — ask the Mazatrol assistant.
Still stuck? Ask the Mazatrol assistant →