CRITICALAlarm code
901
INCORRECT FIXED CYCLE COMMAND (WNo., NNo., BNo.)
What it means
The fixed-cycle command has been set in the program during the tool diameter offset (G41 or G42) modal status.
What to do
- 1Set the tool diameter offset cancellation command (G40) before the fixed-cycle command.
Codebook — decoded
BError typeRegistered Data — program or tool data error
I (L)Stop statusunspecified
O (S)Clearingunspecified
Still faulted after these steps? Do not restart under load — ask the Mazatrol assistant.