ILLEGAL G10 OFFSET No. (WNo., NNo., BNo.)

What it means

Compensation numbers other than the number of sets permitted by the specifications have been designated during input of G10.

What to do
  1. 1After checking the number of compensation sets permitted by the specifications, change the setting of address P to a value smaller than the permissible number of sets.
Codebook — decoded
BError typeRegistered Data — program or tool data error
I (L)Stop statusunspecified
O (S)Clearingunspecified
Still faulted after these steps? Do not restart under load — ask the Mazatrol assistant.