CRITICALAlarm code
952
NO SYNCHRONIZED TAP OPTION (WNo., NNo., BNo.)
What it means
An attempt has been made to perform synchronized tapping in spite of the absence of a synchronized tapping option.
What to do
- 1Synchronized tapping cannot be performed because of the absence of a synchronized tapping option.
Codebook — decoded
BError typeRegistered Data — program or tool data error
I (L)Stop statusunspecified
O (S)Clearingunspecified
Still faulted after these steps? Do not restart under load — ask the Mazatrol assistant.