MACRO MEASUREMENT ALARM 1 ( , )
What it means
1. During execution of the coordinate measurement program, the touch sensor did not come into contact with the workpiece (the skip signal has not turned on) when the maximum feed distance permitted for the skipping speed has been exceeded. 2. During execution of the tool measurement program, the tool did not come into contact with the measuring table (the skip signal did not turn on) when the maximum feed distance permitted for the skipping speed has been exceeded. 3. #3000 = 11 (alarm message) in the user macroprogram was executed.
What to do
- 11.
- 2Check the machining program.
- 32.
- 4Check the tool measurement program.
- 53.
- 6Refer to the relevant user macroprogram instruction manual to check the alarm.
Codebook — decoded
BError typeRegistered Data — program or tool data error
I (L)Stop statusunspecified
O (S)Clearingunspecified