CRITICALAlarm code
991
MACRO MEASUREMENT ALARM 2 ( , )
What it means
1. During execution of the coordinate measurement program, the touch sensor came into contact with the workpiece (the skip signal turned on) when the axes were being fed at other than the skipping speed. 2. During execution of the tool measurement program, the tool came into contact with the measuring table (the skip signal turned on) when the axes were being fed at other than the skipping speed. 3. #3000 = 12 (alarm message) in the user macroprogram was executed.
What to do
- 11.
- 2Check the machining program.
- 3Also check the touch sensor for proper mounting on the spindle.
- 42.
- 5Check the tool measurement program.
- 6Also check that the tools are correctly mounted on the turret.
- 73.
- 8Refer to the relevant user macroprogram instruction manual to check the alarm.
Codebook — decoded
BError typeRegistered Data — program or tool data error
I (L)Stop statusunspecified
O (S)Clearingunspecified
Still faulted after these steps? Do not restart under load — ask the Mazatrol assistant.