CRITICALAlarm code
996

MACRO MEASUREMENT ALARM 7 ( , )

What it means

1. #3000 = 17 (alarm message) in the user macroprogram was executed. 2. In a coordinate measurement unit (plane inclination C measurement), the C-axis inclination angle of the measurement plane is greater than the value set for parameter K221 (maximum C-axis angle variation).

What to do
  1. 11.
  2. 2Refer to the relevant user macroprogram instruction manual to check the alarm.
  3. 32.
  4. 4Check that the touch sensor is in contact with the measurement plane during measurement.
  5. 5In addition, review the value set for parameter K221 (maximum C-axis angle variation).
Codebook — decoded
BError typeRegistered Data — program or tool data error
I (L)Stop statusunspecified
O (S)Clearingunspecified
Still faulted after these steps? Do not restart under load — ask the Mazatrol assistant.