CRITICALAlarm code
997

MACRO MEASUREMENT ALARM 8 ( , )

What it means

1. #3000 = 18 (alarm message) in the user macroprogram was executed. 2. The number of measurements in a coordinate measurement unit (plane inclination C measurement) has exceeded the value set for K222 (number of re-measurements).

What to do
  1. 11.
  2. 2Refer to the relevant user macroprogram instruction manual to check the alarm.
  3. 32.
  4. 4Check that the touch sensor is in contact with the measurement plane during measurement.
  5. 5In addition, review the value set for parameter K223 (permissible difference for skip coordinates X).
Codebook — decoded
BError typeRegistered Data — program or tool data error
I (L)Stop statusunspecified
O (S)Clearingunspecified
Still faulted after these steps? Do not restart under load — ask the Mazatrol assistant.