G-CODEEIA/ISO · modal · group 04
G22

Pre-move stroke check ON

Machine-specific. This G-code reference is specific to the Mazak INTEGREX e-670H / e-670H-S with the MAZATROL SmoothX control (EIA/ISO programming manual H747PB0030E). G-code availability depends on fitted options, and groups and behaviour differ between Mazak models and control generations — verify against the manual for your own machine before programming with any code.
What it does

While stored stroke limit check generates an outside machining prohibit area, the pre-move stroke check function sets an inside machining prohibit area (shaded section in the diagram An alarm will occur beforehand for an axis movement command whose execution would cause the tool to touch, or move in or through the prohibit area. Stored stroke limit , upper limit Stored stroke limit , upper limit Before-movement stroke check, upper (i, j, k) Before-movement stroke check, lower Stored stroke limit , lower limit Stored stroke limit , lower limit

G22 is modal (group 04) — it stays in effect until another code of the same group replaces it.

Programming format
G22 X_ Y_ Z_ I_ J_ K_ (Inside machining prohibitarea specification)
Lower limit specification
Upper limit specification
G23 (Cancellation)
Address words
  • Note: Before setting G22, move the tool to a position outside the prohibit area.
Notes & precautions
  • Before setting G22, move the tool to a position outside the prohibit area.
Source

Mazak PROGRAMMING MANUAL for EIA/ISO PROGRAM, manual H747PB0030E, section 16-1 Pre-move Stroke Check ON/OFF: G22/G23, p. 3-11, 16-1, 16-2, 17-1. Reference and explanation only — not a reproduction of the manual.