G-CODEEIA/ISO · modal · group 09
G85
Fixed cycle (Reaming)
Machine-specific. This G-code reference is specific to the Mazak INTEGREX e-670H / e-670H-S with the MAZATROL SmoothX control (EIA/ISO programming manual H747PB0030E). G-code availability depends on fitted options, and groups and behaviour differ between Mazak models and control generations — verify against the manual for your own machine before programming with any code.
What it does
If, however, f is set equal to 0 or is not set, then the tool is fed at the setting of f .
G85 is modal (group 09) — it stays in effect until another code of the same group replaces it.
Programming format
G85 [Xx Yy] Rr Zz [Pt ] Ff [Ef Dd ]
Address words
- t z : Dwell (in time or No. of revolutions) f 1 : Feed rate 1
- f 0 : Feed rate 0 d 0 : Distance from R-point
- t c : Dwell (in time or No. of revolutions)
Source
Mazak PROGRAMMING MANUAL for EIA/ISO PROGRAM, manual H747PB0030E, section 13-1-16 G85 [Reaming], p. 3-11, 13-18. Reference and explanation only — not a reproduction of the manual.