PARAMMachine parameter · BARRIER (BA)
BA105
Adjustment “FdT” for servo axis thrust hold
Machine-specific. This parameter list is specific to the Mazak INTEGREX e-670H / e-670H-S with the MAZATROL SmoothX control (manual HA64HA0035E). Other Mazak models and control generations use different addresses, ranges and meanings — verify on your own control before changing anything.
What it does
Adjustment “FdT” for servo axis thrust hold
Set adjustment “FdT” for holding the thrust of the servo axis. Set a value less than × BA106/100. If any other value is set, the thrust may be unstable.
Setting
Setting range0 to 99999999
Unit0.0005 mm/0.000005 in
Program typeM, E
Takes effectAfter stop of movement
Source
Mazak PARAMETER LIST / ALARM LIST / M-CODE LIST, manual HA64HA0035E, p. 93, 593. Reference and explanation only — not a reproduction of the manual.