PARAMMachine parameter · BARRIER (BA)
BA107
Filter
Machine-specific. This parameter list is specific to the Mazak INTEGREX e-670H / e-670H-S with the MAZATROL SmoothX control (manual HA64HA0035E). Other Mazak models and control generations use different addresses, ranges and meanings — verify on your own control before changing anything.
What it does
Filter
Set the monitoring time for changes in the drooping level of the servo axis thrust.
Setting
Setting range0 to 99999999
Unit1/3.5 ms
Program typeM, E
Takes effectAfter stop of movement
Source
Mazak PARAMETER LIST / ALARM LIST / M-CODE LIST, manual HA64HA0035E, p. 93, 593. Reference and explanation only — not a reproduction of the manual.