PARAMMachine parameter · BARRIER (BA)
BA126

BARRIER bit settings (8 bits)

Machine-specific. This parameter list is specific to the Mazak INTEGREX e-670H / e-670H-S with the MAZATROL SmoothX control (manual HA64HA0035E). Other Mazak models and control generations use different addresses, ranges and meanings — verify on your own control before changing anything.
Bit settings — BA126 is set bit by bit
  1. bit 0

    System to be made valid without system selection for queuing

    Takes effect: Immediate

  2. bit 1

    Y-axis interference type

    Takes effect: Immediate

  3. bit 2

    Y-axis moving range display

    Takes effect: Immediate

  4. bit 3

    Tool command scheme

    Takes effect: Immediate

  5. bit 4

    FLASH tool valid/invalid

    Takes effect: Immediate

  6. bit 5

    Milling spindle orientation command (M219), output/no output

    Takes effect: Immediate

  7. bit 6

    System without turret

    Takes effect: Immediate

  8. bit 7

    Shape of the tailstock center for Virtual Machining, single stage/twin stage

    Takes effect: Immediate

Source

Mazak PARAMETER LIST / ALARM LIST / M-CODE LIST, manual HA64HA0035E, p. 94, 598. Reference and explanation only — not a reproduction of the manual.

Not sure what to set? Ask the Mazatrol assistant →