PARAMMachine parameter · BARRIER (BA)
BA68
Deceleration area X
Machine-specific. This parameter list is specific to the Mazak INTEGREX e-670H / e-670H-S with the MAZATROL SmoothX control (manual HA64HA0035E). Other Mazak models and control generations use different addresses, ranges and meanings — verify on your own control before changing anything.
What it does
G36 deceleration area G36 measuring area
Set the deceleration area and measuring area in the G36 command. BA68: Set the distance between the starting point of movement at the measuring rate, and the measuring point. This value will be used when argument R is omitted from the G36 command. BA69: Set the moving distance in measuring feed mode. This value will be used when argument D is omitted from the G36 command.
Setting
Setting range0 to 99999999
Unit—
Program typeM, E
Takes effectAfter stop of movement
Source
Mazak PARAMETER LIST / ALARM LIST / M-CODE LIST, manual HA64HA0035E, p. 92, 588. Reference and explanation only — not a reproduction of the manual.