PARAMMachine parameter · BARRIER (BA)
BA83-BA86
Barrier setup chuck reference position 2
Machine-specific. This parameter list is specific to the Mazak INTEGREX e-670H / e-670H-S with the MAZATROL SmoothX control (manual HA64HA0035E). Other Mazak models and control generations use different addresses, ranges and meanings — verify on your own control before changing anything.
What it does
Barrier setup chuck reference position 2
Set the chuck reference position 2 to be used to set barrier around jaws for a program without jaw No. setting. Use J113 to J116 for machines with the No. 2 spindle set as System 1.
Setting
Setting range±99999999
Unit0.001 mm/0.0001 in
Program typeM, E
Takes effectImmediate
Source
Mazak PARAMETER LIST / ALARM LIST / M-CODE LIST, manual HA64HA0035E, p. 92, 590. Reference and explanation only — not a reproduction of the manual.