PARAMMachine parameter · BARRIER (BA)
BA87-BA90

Barrier reference position for a powered tailstock

Machine-specific. This parameter list is specific to the Mazak INTEGREX e-670H / e-670H-S with the MAZATROL SmoothX control (manual HA64HA0035E). Other Mazak models and control generations use different addresses, ranges and meanings — verify on your own control before changing anything.
What it does

Barrier reference position for a powered tailstock

Set the reference position for barrier area of a powered tailstock. Use coordinates with respect to the machine zero point of the upper turret to set the position of the tailstock being not used for machining. When the tailstock is used, the barrier will be provided at the position shifted through the distance of R10366 (lower-order)/R10367 (higher-order) in the Z-axis direction, from the position specified above. For machines with multiple systems use only parameters for System 1.

Setting
Setting range±99999999
Unit0.001 mm/0.0001 in
Program typeM, E
Takes effectImmediate
Source

Mazak PARAMETER LIST / ALARM LIST / M-CODE LIST, manual HA64HA0035E, p. 92, 591. Reference and explanation only — not a reproduction of the manual.

Not sure what to set? Ask the Mazatrol assistant →