PARAMUser parameter · POINT (D)
D44
Selecting an automatic calculation method for the amount of chamfer with the tapping unit
Machine-specific. This parameter list is specific to the Mazak INTEGREX e-670H / e-670H-S with the MAZATROL SmoothX control (manual HA64HA0035E). Other Mazak models and control generations use different addresses, ranges and meanings — verify on your own control before changing anything.
What it does
Selecting an automatic calculation method for the amount of chamfer with the tapping unit
Select an automatic calculation method for the amount of chamfer with the tapping unit. 0: Following calculation expression is used: (MAJOR- + 2 × PITCH) – PRE-DIA Amount of chamfer = 1: Following calculation expression is used (same as M32): Amount of chamfer = Note : Select 1 if a loss of the threaded section is likely due to overchamfering as compared with a small TAP-DEP value. Example : Sheet metal tapping
Setting
Setting range0, 1
Unit—
Program typeM
Takes effectImmediate
Source
Mazak PARAMETER LIST / ALARM LIST / M-CODE LIST, manual HA64HA0035E, p. 20, 115. Reference and explanation only — not a reproduction of the manual.