PARAMUser parameter · POINT (D)
D46

Minimum gradual drilling depth

Machine-specific. This parameter list is specific to the Mazak INTEGREX e-670H / e-670H-S with the MAZATROL SmoothX control (manual HA64HA0035E). Other Mazak models and control generations use different addresses, ranges and meanings — verify on your own control before changing anything.
What it does

Minimum gradual drilling depth

Set the minimum gradual drilling depth. However, if the residual hole depth is smaller than D46, actual drilling depth will be the same as the residual hole depth. (D45)

Setting
Setting range0 to 9999
Unit0.01 mm/0.001 in
Program typeM
Takes effectImmediate
Source

Mazak PARAMETER LIST / ALARM LIST / M-CODE LIST, manual HA64HA0035E, p. 20, 115. Reference and explanation only — not a reproduction of the manual.