PARAMUser parameter · POINT (D)
D49
Amount of return at hole bottom during the planetary tapping cycle
Machine-specific. This parameter list is specific to the Mazak INTEGREX e-670H / e-670H-S with the MAZATROL SmoothX control (manual HA64HA0035E). Other Mazak models and control generations use different addresses, ranges and meanings — verify on your own control before changing anything.
What it does
Amount of return at hole bottom during the planetary tapping cycle
The amount of return at hole bottom during the planetary tapping cycle Specify data by the number of threads. Amount of return = Tapping pitch × D49/10
Setting
Setting range0 to 999
Unit0.1 thread
Program typeM
Takes effectImmediate
Source
Mazak PARAMETER LIST / ALARM LIST / M-CODE LIST, manual HA64HA0035E, p. 20, 116. Reference and explanation only — not a reproduction of the manual.