PARAMUser parameter · POINT (D)
D5
Prehole through speed during inversed spot-facing
Machine-specific. This parameter list is specific to the Mazak INTEGREX e-670H / e-670H-S with the MAZATROL SmoothX control (manual HA64HA0035E). Other Mazak models and control generations use different addresses, ranges and meanings — verify on your own control before changing anything.
What it does
Prehole through speed during inversed spot-facing
The feed rate of a tool as it is being passed through the prehole during an inversed spot-facing cycle Note : 0.5 mm/rev if this parameter setting is 0.
Setting
Setting range0 to 99
Unit100 mm/min / 10 in/min
Program typeM
Takes effectImmediate
Source
Mazak PARAMETER LIST / ALARM LIST / M-CODE LIST, manual HA64HA0035E, p. 19, 104. Reference and explanation only — not a reproduction of the manual.