PARAMUser parameter · POINT (D)
D50

Auto-set feed rate for pre-hole machining in the planetary tapping cycle

Machine-specific. This parameter list is specific to the Mazak INTEGREX e-670H / e-670H-S with the MAZATROL SmoothX control (manual HA64HA0035E). Other Mazak models and control generations use different addresses, ranges and meanings — verify on your own control before changing anything.
What it does

Auto-set feed rate for pre-hole machining in the planetary tapping cycle

The feed rate for pre-hole machining will be auto-set to D50 when the planetary tapping cycle is selected. SNo. TOOL NOM- No.HOLE- HOLE-DEP PRE-DIA PRE-DEP RGH DEPTH C-SP FR M M 1 TAP M10. 10. 23.7 PLANET 0.15 FIX P1.5 50 1.5

Setting
Setting range0 to 9999
Unit—
Program typeM
Takes effectImmediate
Source

Mazak PARAMETER LIST / ALARM LIST / M-CODE LIST, manual HA64HA0035E, p. 20, 116. Reference and explanation only — not a reproduction of the manual.

Not sure what to set? Ask the Mazatrol assistant →