PARAMUser parameter · POINT (D)
D51
Auto-set feed rate for planetary tapping cycle
Machine-specific. This parameter list is specific to the Mazak INTEGREX e-670H / e-670H-S with the MAZATROL SmoothX control (manual HA64HA0035E). Other Mazak models and control generations use different addresses, ranges and meanings — verify on your own control before changing anything.
What it does
Auto-set feed rate for planetary tapping cycle
The feed rate will be auto-set to D51 when the planetary tapping cycle is selected. SNo. TOOL NOM- No.HOLE- HOLE-DEP PRE-DIA PRE-DEP RGH DEPTH C-SP FR M M 1 TAP M10. 10. 23.7 PLANET 0.15 FIX P1.5 50 0.04
Setting
Setting range0 to 9999
Unit—
Program typeM
Takes effectImmediate
Source
Mazak PARAMETER LIST / ALARM LIST / M-CODE LIST, manual HA64HA0035E, p. 20, 117. Reference and explanation only — not a reproduction of the manual.