PARAMData I/O parameter · DNC (DNC)
DNC11
Number of NC transmission/reception retries during DNC command message transfer
Machine-specific. This parameter list is specific to the Mazak INTEGREX e-670H / e-670H-S with the MAZATROL SmoothX control (manual HA64HA0035E). Other Mazak models and control generations use different addresses, ranges and meanings — verify on your own control before changing anything.
What it does
Number of NC transmission/reception retries during DNC command message transfer
This parameter is used to set the number of times that transmission/reception of command messages is to be repeated in the case that it is not correctly performed. This parameter has almost the same meaning as that of parameters DNC9 and DNC10, except that command messages are interchanged in the case of DNC11 and files are interchanged in the case of DNC9 and DNC10.
Setting
Setting range0 to 255
UnitNumber of times
Program typeM, E
Takes effectAt I/O startup
Source
Mazak PARAMETER LIST / ALARM LIST / M-CODE LIST, manual HA64HA0035E, p. 97, 624. Reference and explanation only — not a reproduction of the manual.