PARAMData I/O parameter · DNC (DNC)
DNC18

DNC command reply message waiting time

Machine-specific. This parameter list is specific to the Mazak INTEGREX e-670H / e-670H-S with the MAZATROL SmoothX control (manual HA64HA0035E). Other Mazak models and control generations use different addresses, ranges and meanings — verify on your own control before changing anything.
What it does

DNC command reply message waiting time

The NC waiting time from transmission of command message EOT to reception of command reply message  from the host system. Command reply messages

Setting
Setting range0 to 255
Unit0.1 s
Program typeM, E
Takes effectAt I/O startup
Source

Mazak PARAMETER LIST / ALARM LIST / M-CODE LIST, manual HA64HA0035E, p. 97, 626. Reference and explanation only — not a reproduction of the manual.

Not sure what to set? Ask the Mazatrol assistant →