DNC bit settings (8 bits)

Machine-specific. This parameter list is specific to the Mazak INTEGREX e-670H / e-670H-S with the MAZATROL SmoothX control (manual HA64HA0035E). Other Mazak models and control generations use different addresses, ranges and meanings — verify on your own control before changing anything.
Bit settings — DNC26 is set bit by bit
  1. bit 0

    After program reception, a search is made/not made for the work number of that program.

    Takes effect: At I/O startup

  2. bit 1

    Details of an alarm occurring in DNC are displayed or not.

    Takes effect: At I/O startup

  3. bit 2

    Loading of programs having the same work number as that of the registered program in NC becomes impossible or not.

    Takes effect: At I/O startup

  4. bit 3

    The function of the PROGRAM LOCK/ ENABLE switch is released or not.

    Takes effect: At I/O startup

  5. bit 4

    —

    Takes effect: At I/O startup

  6. bit 5

    Three digit G-format and G10 format codes input/output for MAZAK data transfer protocol

    Takes effect: At I/O startup

  7. bit 6

    Binary to ASCII format input/output of MAZAK data transfer protocol

    Takes effect: At I/O startup

  8. bit 7

    All programs having work numbers smaller than No. 9000 are erased/not erased at the start of program reception.

    Takes effect: At I/O startup

Source

Mazak PARAMETER LIST / ALARM LIST / M-CODE LIST, manual HA64HA0035E, p. 98, 627. Reference and explanation only — not a reproduction of the manual.