Bit settings — DNC26 is set bit by bit
- bit 0
After program reception, a search is made/not made for the work number of that program.
- bit 1
Details of an alarm occurring in DNC are displayed or not.
- bit 2
Loading of programs having the same work number as that of the registered program in NC becomes impossible or not.
- bit 3
The function of the PROGRAM LOCK/ ENABLE switch is released or not.
- bit 4
—
- bit 5
Three digit G-format and G10 format codes input/output for MAZAK data transfer protocol
- bit 6
Binary to ASCII format input/output of MAZAK data transfer protocol
- bit 7
All programs having work numbers smaller than No. 9000 are erased/not erased at the start of program reception.
Source
Mazak PARAMETER LIST / ALARM LIST / M-CODE LIST, manual HA64HA0035E, p. 98, 627. Reference and explanation only — not a reproduction of the manual.