Method of handshaking
Machine-specific. This parameter list is specific to the Mazak INTEGREX e-670H / e-670H-S with the MAZATROL SmoothX control (manual HA64HA0035E). Other Mazak models and control generations use different addresses, ranges and meanings — verify on your own control before changing anything.
What it does
Method of handshaking
This parameter is used to select the method of handshaking to control the state of data transfer between the NC system and connected device. Set values Method Description 0 None No control 1 DC control Complies with control code DC1 through DC4 2 RTS/CTS Complies with device connection RTS/CTS.
Setting
Setting range0 to 2
Unit—
Program typeM, E
Takes effectAt I/O startup
Source
Mazak PARAMETER LIST / ALARM LIST / M-CODE LIST, manual HA64HA0035E, p. 99, 636. Reference and explanation only — not a reproduction of the manual.