PARAMUser parameter · LINE/FACE/3D (E)
E78
3-D, Multiplying factor set for tolerance
Machine-specific. This parameter list is specific to the Mazak INTEGREX e-670H / e-670H-S with the MAZATROL SmoothX control (manual HA64HA0035E). Other Mazak models and control generations use different addresses, ranges and meanings — verify on your own control before changing anything.
What it does
3-D Multiplying factor set for tolerance
0: 100%
Setting
Setting range0 to 100
Unit%
Program typeM
Takes effectImmediate
Source
Mazak PARAMETER LIST / ALARM LIST / M-CODE LIST, manual HA64HA0035E, p. 25, 151. Reference and explanation only — not a reproduction of the manual.