PARAMUser parameter · EIA/ISO (F)
F102
Fine spline interpolation curve error (Block including the point of inflection)
Machine-specific. This parameter list is specific to the Mazak INTEGREX e-670H / e-670H-S with the MAZATROL SmoothX control (manual HA64HA0035E). Other Mazak models and control generations use different addresses, ranges and meanings — verify on your own control before changing anything.
What it does
Fine spline interpolation curve error (Block including the point of inflection)
During block checking in the fine spline interpolation mode, if the spline curve of a specific block is judged to include an inflection point and the maximum chord error between the spline curve and the block is larger than the value of F102, the shape of the curve will be modified to reduce the maximum chord error below the value of F102. A B
Setting
Setting range0 to 99999999
Unit0.0001 mm/0.00001 in
Program typeE
Takes effectImmediate
Source
Mazak PARAMETER LIST / ALARM LIST / M-CODE LIST, manual HA64HA0035E, p. 36, 216. Reference and explanation only — not a reproduction of the manual.