PARAMUser parameter · EIA/ISO (F)
F113

EIA/ISO bit settings (8 bits)

Machine-specific. This parameter list is specific to the Mazak INTEGREX e-670H / e-670H-S with the MAZATROL SmoothX control (manual HA64HA0035E). Other Mazak models and control generations use different addresses, ranges and meanings — verify on your own control before changing anything.
Bit settings — F113 is set bit by bit
  1. bit 0

    Counting all types of use under the same tool number for the tool life management on the TOOL DATA display executed/not executed

    F113 (bit 0) = 0: Counting each type of use under the same tool number individually. F113 (bit 0) = 1: Counting all types of use under the same tool number integratingly.

    Range 0, 1 · Takes effect: Immediate

  2. bit 1

    Data handling on the milling tool of a group that has expired in tool life

    F113 (bit 1) = 0: Operation will be continued. F113 (bit 1) = 1: Operation will be stopped.

    Range 0, 1 · Takes effect: Immediate

  3. bit 2

    Data handling on the turning tool of a group that has expired in tool life

    F113 (bit 2) = 0: Operation will be continued. F113 (bit 2) = 1: Operation will be stopped.

    Range 0, 1 · Takes effect: Immediate

  4. bit 3

    Tool life management of the FLASH tool

    Select whether the FLASH tool that has been registered under the same tool number for the tool life management function is to be included in spare tools. F113 (bit 3) = 0: The FLASH tool will be included in spare tools. F113 (bit 3) = 1: The FLASH tool will not be included in spare tools.

    Range 0, 1 · Takes effect: Immediate

  5. bit 4

    Tool life management — Life time

    Select whether the life time on the TOOL DATA display is to be included in the life judgment items listed for the tool life management function. F113 (bit 4) = 0: The life time will be included in the life judgment items. F113 (bit 4) = 1: The life time will not be included in the life judgment items.

    Range 0, 1 · Takes effect: Immediate

  6. bit 5

    Tool life management – Maximum available wear offset data X

    Select whether the maximum available wear offset data X on the TOOL DATA display is to be included in the life judgment items listed for the tool life management function. F113 (bit 5) = 0: The maximum available wear offset data X will be included in the life judgment items. F113 (bit 5) = 1: The maximum available wear offset data X will not be included in the life judgment items.

    Range 0, 1 · Takes effect: Immediate

  7. bit 6

    Tool life management — Maximum available wear offset data Y

    Select whether the maximum available wear offset data Y on the TOOL DATA display is to be included in the life judgment items listed for the tool life management function. F113 (bit 6) = 0: The maximum available wear offset data Y will be included in the life judgment items. F113 (bit 6) = 1: The maximum available wear offset data Y will not be included in the life judgment items.

    Range 0, 1 · Takes effect: Immediate

  8. bit 7

    Tool life management — Maximum available wear offset data Z

    Select whether the maximum available wear offset data Z on the TOOL DATA display is to be included in the life judgment items listed for the tool life management function. F113 (bit 7) = 0: The maximum available wear offset data Z will be included in the life judgment items. F113 (bit 7) = 1: The maximum available wear offset data Z will not be included in the life judgment items.

    Range 0, 1 · Takes effect: Immediate

Source

Mazak PARAMETER LIST / ALARM LIST / M-CODE LIST, manual HA64HA0035E, p. 36, 37, 220, 221, 222. Reference and explanation only — not a reproduction of the manual.

Not sure what to set? Ask the Mazatrol assistant →