PARAMUser parameter · EIA/ISO (F)
F118

Feed rate of the threading runout — Z-axis

Machine-specific. This parameter list is specific to the Mazak INTEGREX e-670H / e-670H-S with the MAZATROL SmoothX control (manual HA64HA0035E). Other Mazak models and control generations use different addresses, ranges and meanings — verify on your own control before changing anything.
What it does

Feed rate of the threading runout – Z-axis

Specify the Z-axial feed rate for the runout of the threading cycle. A quarter (1/4) of the rapid traverse (as set in parameter M1) applies when this parameter is set to zero (0). In case of M1 < F118, the feed rate will be clamped with the M1 value.

Setting
Setting range0 to 240000
Unitmm/min
Program typeM, E
Takes effectImmediate
Source

Mazak PARAMETER LIST / ALARM LIST / M-CODE LIST, manual HA64HA0035E, p. 37, 225. Reference and explanation only — not a reproduction of the manual.