PARAMUser parameter · EIA/ISO (F)
F124

Permissible data alteration amount 1 for input error prevention function

Machine-specific. This parameter list is specific to the Mazak INTEGREX e-670H / e-670H-S with the MAZATROL SmoothX control (manual HA64HA0035E). Other Mazak models and control generations use different addresses, ranges and meanings — verify on your own control before changing anything.
What it does

Permissible data alteration amount 1 for input error prevention function

The data input in the following items are checked based on the permissible data alteration amount set in this parameter. TOOL DATA: LENGTH, ACT-, TOOL SET X, TOOL SET Z, LENG COMP., LENG.CO., ACT-CO. TOOL OFFFSET: GEOMETRIC OFFSET

Setting
Setting range0 to 99999999
Unit0.0001 mm/0.00001 in
Program typeM, E
Takes effectImmediate
Source

Mazak PARAMETER LIST / ALARM LIST / M-CODE LIST, manual HA64HA0035E, p. 37, 228. Reference and explanation only — not a reproduction of the manual.

Not sure what to set? Ask the Mazatrol assistant →