PARAMUser parameter · EIA/ISO (F)
F145
Rapid feed override when data alteration is detected
Machine-specific. This parameter list is specific to the Mazak INTEGREX e-670H / e-670H-S with the MAZATROL SmoothX control (manual HA64HA0035E). Other Mazak models and control generations use different addresses, ranges and meanings — verify on your own control before changing anything.
What it does
Rapid feed override when data alteration is detected
The rapid feed rate override is reduced to the value set here, when data alteration is detected. This value will be handled as100 if 0 is set here.
Setting
Setting range0 to 100
Unit%
Program typeM
Takes effectImmediate
Source
Mazak PARAMETER LIST / ALARM LIST / M-CODE LIST, manual HA64HA0035E, p. 38, 235. Reference and explanation only — not a reproduction of the manual.