PARAMUser parameter · EIA/ISO (F)
F150
Output data offset of NC basic information for field network
Machine-specific. This parameter list is specific to the Mazak INTEGREX e-670H / e-670H-S with the MAZATROL SmoothX control (manual HA64HA0035E). Other Mazak models and control generations use different addresses, ranges and meanings — verify on your own control before changing anything.
What it does
Output data offset of NC basic information for field network
Set the top register R (R18176 to R18463) for output destination of NC basic information for field network. Example : 1. When F150 = 0 2. When F150 = 352 Data output to NC basic information Note : If a value set for F150 is out of the setting range or is an odd value, alarm 528 FIELDNETWORK SETTING ERROR (4, , ) occurs and the communication stops. NC basic information will not be output.
Setting
Setting range0 to 352
Unit—
Program typeM, E
Takes effectImmediate
Source
Mazak PARAMETER LIST / ALARM LIST / M-CODE LIST, manual HA64HA0035E, p. 38, 237. Reference and explanation only — not a reproduction of the manual.