PARAMUser parameter · EIA/ISO (F)
F155

EIA/ISO bit settings (4 bits)

Machine-specific. This parameter list is specific to the Mazak INTEGREX e-670H / e-670H-S with the MAZATROL SmoothX control (manual HA64HA0035E). Other Mazak models and control generations use different addresses, ranges and meanings — verify on your own control before changing anything.
Bit settings — F155 is set bit by bit
  1. bit 0

    Material geometry display for programs converted into the EIA format

    Display of material based on the geometry data in the programs output during EIA conversion in virtual machining, 3D setup, and the 3D interference check 0: Not displayed 1: Displayed *1 After changing the parameter settings, the settings may not be reflected in drawings on the 3D MONITOR display. In such cases, tap [DRAW WORKPCE MATERIAL] on the 3D MONITOR display. *2 When F89 bit 0 = 1, geometry data can be output by executing EIA conversion.

    Range 0, 1 · Takes effect: Immediate

  2. bit 3

    Operation when argument I is omitted from the tap cycle command having argument Q

    Operation when argument I is omitted from the tap cycle command having argument Q 0: Operation as a deep-hole cycle 1: Operation as a high-speed deep-hole cycle

    Range 0, 1 · Takes effect: At power on

  3. bit 5

    Setup data editing during automatic GL operation, disabled/enabled

    Setup data editing during automatic GL operation 0: Editing disabled (alarm 428 MEMORY PROTECT (AUTO OPERATION) occurs) 1: Editing enabled (only during single-block stop or feed hold stop)

    Range 0, 1 · Takes effect: Immediate

  4. bit 7

    Setting of the spindle to be displayed in the results of machining navigation for the mill-turning unit

    Sets the spindle to be displayed in the results of machining navigation for the mill-turning unit 0: Milling spindle 1: Turning Spindle

    Range 0, 1 · Takes effect: After stop of movement

Source

Mazak PARAMETER LIST / ALARM LIST / M-CODE LIST, manual HA64HA0035E, p. 39, 240. Reference and explanation only — not a reproduction of the manual.