PARAMUser parameter · EIA/ISO (F)
F164

EIA/ISO bit settings (6 bits)

Machine-specific. This parameter list is specific to the Mazak INTEGREX e-670H / e-670H-S with the MAZATROL SmoothX control (manual HA64HA0035E). Other Mazak models and control generations use different addresses, ranges and meanings — verify on your own control before changing anything.
Bit settings — F164 is set bit by bit
  1. bit 0

    Automatic tool data setting conditions Magazine (turret) tool

    0: Enabled 1: Disabled

    Range 0, 1 · Takes effect: After stop of movement

  2. bit 2

    PROGRAM LAYOUT display save function selection

    When the layout has been saved on the PROGRAM LAYOUT display, the saved layout is retained or not if the WNo. is changed on the PROGRAM display or the program is edited. 0: Do not retain 1: Retain Note : When F164 bit 2 = 1, the priority number cannot be written in the save enabled status. The priority number cannot be written when the WNo. on the PROGRAM display is changed in the save enabled status.

    Range 0, 1

  3. bit 4

    Automatic tool data setting conditions Invalid tools

    0: Enabled 1: Disabled

    Range 0, 1 · Takes effect: After stop of movement

  4. bit 5

    Automatic tool data setting conditions Broken tools

    0: Enabled 1: Disabled

    Range 0, 1 · Takes effect: After stop of movement

  5. bit 6

    Automatic tool data setting conditions Expired tools

    0: Enabled 1: Disabled

    Range 0, 1 · Takes effect: After stop of movement

  6. bit 7

    Automatic tool data setting conditions Life warning tools

    0: Enabled 1: Disabled

    Range 0, 1 · Takes effect: After stop of movement

Source

Mazak PARAMETER LIST / ALARM LIST / M-CODE LIST, manual HA64HA0035E, p. 41, 256, 257. Reference and explanation only — not a reproduction of the manual.

Not sure what to set? Ask the Mazatrol assistant →