PARAMUser parameter · EIA/ISO (F)
F19

Maximum permissible difference in arc radius

Machine-specific. This parameter list is specific to the Mazak INTEGREX e-670H / e-670H-S with the MAZATROL SmoothX control (manual HA64HA0035E). Other Mazak models and control generations use different addresses, ranges and meanings — verify on your own control before changing anything.
What it does

Maximum permissible difference in arc radius

Maximum radius difference that causes spiral interpolation to be performed when the arc-drawing start point and end point radii that have been specified in the arc command do not agree.

Setting
Setting range0 to 9999
Unit0.0001 mm/0.00001 in
Program typeM, E
Takes effectNext block
Source

Mazak PARAMETER LIST / ALARM LIST / M-CODE LIST, manual HA64HA0035E, p. 28, 176. Reference and explanation only — not a reproduction of the manual.

Not sure what to set? Ask the Mazatrol assistant →