PARAMUser parameter · EIA/ISO (F)
F300
INTELLIGENT SAFETY SHIELD: Cutting accuracy
Machine-specific. This parameter list is specific to the Mazak INTEGREX e-670H / e-670H-S with the MAZATROL SmoothX control (manual HA64HA0035E). Other Mazak models and control generations use different addresses, ranges and meanings — verify on your own control before changing anything.
What it does
INTELLIGENT SAFETY SHIELD: Cutting accuracy
Set the cutting accuracy to be taken into consideration for the INTELLIGENT SAFETY SHIELD function during automatic operation.
Setting
Setting range1000 to 20000
Unit0.0001 mm
Program typeM, E
Takes effectAt power on
Source
Mazak PARAMETER LIST / ALARM LIST / M-CODE LIST, manual HA64HA0035E, p. 43, 268. Reference and explanation only — not a reproduction of the manual.