PARAMUser parameter · EIA/ISO (F)
F301
INTELLIGENT SAFETY SHIELD: Tool path accuracy for collision check processing
Machine-specific. This parameter list is specific to the Mazak INTEGREX e-670H / e-670H-S with the MAZATROL SmoothX control (manual HA64HA0035E). Other Mazak models and control generations use different addresses, ranges and meanings — verify on your own control before changing anything.
What it does
INTELLIGENT SAFETY SHIELD: Tool path accuracy for collision check processing
Set the tool path accuracy to be taken into consideration for the collision check processing by the INTELLIGENT SAFETY SHIELD function.
Setting
Setting range1000 to 20000
Unit0.0001 mm
Program typeM, E
Takes effectImmediate
Source
Mazak PARAMETER LIST / ALARM LIST / M-CODE LIST, manual HA64HA0035E, p. 43, 268. Reference and explanation only — not a reproduction of the manual.