PARAMUser parameter · EIA/ISO (F)
F301

INTELLIGENT SAFETY SHIELD: Tool path accuracy for collision check processing

Machine-specific. This parameter list is specific to the Mazak INTEGREX e-670H / e-670H-S with the MAZATROL SmoothX control (manual HA64HA0035E). Other Mazak models and control generations use different addresses, ranges and meanings — verify on your own control before changing anything.
What it does

INTELLIGENT SAFETY SHIELD: Tool path accuracy for collision check processing

Set the tool path accuracy to be taken into consideration for the collision check processing by the INTELLIGENT SAFETY SHIELD function.

Setting
Setting range1000 to 20000
Unit0.0001 mm
Program typeM, E
Takes effectImmediate
Source

Mazak PARAMETER LIST / ALARM LIST / M-CODE LIST, manual HA64HA0035E, p. 43, 268. Reference and explanation only — not a reproduction of the manual.

Not sure what to set? Ask the Mazatrol assistant →