PARAMUser parameter · EIA/ISO (F)
F304
Alarm wait time during [CUT] restarting search during VIRTUAL MACHINING
Machine-specific. This parameter list is specific to the Mazak INTEGREX e-670H / e-670H-S with the MAZATROL SmoothX control (manual HA64HA0035E). Other Mazak models and control generations use different addresses, ranges and meanings — verify on your own control before changing anything.
What it does
Alarm wait time during [CUT] restarting search during VIRTUAL MACHINING
Sets the wait time when an alarm is detected during restarting search initiated by pressing [CUT] during VIRTUAL MACHINING. When an alarm has been detected, the restarting search is resumed if the alarm is canceled within the set wait time or stopped with alarm 2120 RESTART PT SEARCH INTERRUPTED generated if it is not canceled even after the wait time has elapsed. When this parameter is set to “0”, the wait time is 10 seconds.
Setting
Setting range0 to 99999999
Unitms
Program typeM, E
Takes effectImmediate
Source
Mazak PARAMETER LIST / ALARM LIST / M-CODE LIST, manual HA64HA0035E, p. 44, 269. Reference and explanation only — not a reproduction of the manual.