PARAMUser parameter · EIA/ISO (F)
F329

EIA/ISO bit settings (4 bits)

Machine-specific. This parameter list is specific to the Mazak INTEGREX e-670H / e-670H-S with the MAZATROL SmoothX control (manual HA64HA0035E). Other Mazak models and control generations use different addresses, ranges and meanings — verify on your own control before changing anything.
Bit settings — F329 is set bit by bit
  1. bit 0

    Operation at specification of undefined SMC data number

    Used to select the operation when an undefined SMC data number or an SMC data number outside the permissible range has been specified with an SMC data specification command (G61.1P) in EIA/ISO programs. 0: Continue operation without changing the SMC data number with the alarm 965 DESIGNATED PNo NOT FOUND displayed. Note, however, if this alarm is generated during a tool path check, the tool path check operation stops. 1: Stop operation with the alarm 964 DESIGNATED PNo NOT FOUND displayed.

    Range 0, 1 · Takes effect: Immediate

  2. bit 2

    Mating tool selection function for automatic tool length setting of FLASH tool

    Function to select the mating tool when setting the tool length automatically for a FLASH tool on the TOOL DATA display. 0: Invalid 1: Valid

    Range 0, 1 · Takes effect: Immediate

  3. bit 3

    Automatic M code output for smooth restart

    Select whether the M codes related to spindle rotation are to be automatically output when executing the smooth restart function. 0: Output automatically 1: Do not output automatically

    Range 0, 1 · Takes effect: Immediate

  4. bit 4

    Operation to return to the restarting position for smooth restart

    Select the operation of the axes for which no movement is specified in the program when returning the axes to the restarting position for the smooth restart function. 0: Move the axes for which no movement is specified in the program to the machine zero point. 1: Do not move the axes for which no movement is specified in the program to the machine zero point.

    Range 0, 1 · Takes effect: Immediate

Source

Mazak PARAMETER LIST / ALARM LIST / M-CODE LIST, manual HA64HA0035E, p. 44, 271. Reference and explanation only — not a reproduction of the manual.

Not sure what to set? Ask the Mazatrol assistant →