EIA/ISO bit settings (8 bits)
- bit 0
Cancellation of the ram spindle offset command (G52.1) when the RESET key is pressed valid/invalid
0: Invalid (G52.1 hold) 1: Valid
- bit 1
Representation on the POSITION display for G49 (only for the INTEGREX e Series)
The data number and value for tool length offset on the POSITION display upon execution of a G49 (Tool length offset OFF) command 0: Not changed at all 1: Reset to zero (0)
- bit 2
Parts count override in the middle of automatic operation
To manually override the parts count (current number of machined workpieces) in the middle of automatic operation 0: Impossible (The operation caused by the ATC and RETURN settings in the end unit occurs with respect to the parts count.) 1: Possible (The operation caused by the ATC and RETURN settings in the end unit occurs irrespectively of the parts count.)
- bit 3
Tool change command output position of the tool to use in manual program unit when WPC is selected for workpiece scheme
Set the tool change command output position of the tool to use in manual program unit when WPC is selected for workpiece scheme. 0: Always output at the machining end position of the previous unit. 1: Set the output position in manual program unit. (“RETURN” is automatically set at the same time as default.)
- bit 4
Programming type for inclined-surface machining
0: Type A (5-axis machining available) 1: Type B (MPro compatible)
- bit 5
Current position display of the tool nose at reset
0: Display the B-axis rotational center position. 1: Display the tool tip position when a MAZATROL program is selected or when MAZATROL tool length is valid (bit 3 of parameter F93 is set to 1).
- bit 6
Compensating movement for a T-code with a movement command in one block
0: No compensating movement on an unspecified axis till completion of the specified movement 1: Simultaneous compensating movement on all the axes including un- specified one, on condition that the tool number is not changed * Bit 6 of F34 is valid only when G-code series T (Turning machines) is selected and F161 bit 2 is set to 1.
- bit 7
Application of Z-OFFSET and C-OFFSET values for the tape operation mode
0: Application of the Z-OFFSET and C-OFFSET values prepared for the program that is currently selected from the STANDARD PROGRAM storage area for the automatic operation 1: No application of the Z-OFFSET and C-OFFSET values prepared on the SETUP INFORMATION display
Mazak PARAMETER LIST / ALARM LIST / M-CODE LIST, manual HA64HA0035E, p. 29, 180, 181, 182. Reference and explanation only — not a reproduction of the manual.