PARAMUser parameter · EIA/ISO (F)
F35

EIA/ISO bit settings (7 bits)

Machine-specific. This parameter list is specific to the Mazak INTEGREX e-670H / e-670H-S with the MAZATROL SmoothX control (manual HA64HA0035E). Other Mazak models and control generations use different addresses, ranges and meanings — verify on your own control before changing anything.
Bit settings — F35 is set bit by bit
  1. bit 0

    Selection whether or not multiple material pieces can be arranged on the VIRTUAL MACHINING or 3D MONITOR display

    Select whether or not multiple material pieces can be arranged on the VIRTUAL MACHINING or 3D MONITOR display. 0: Arrangement of a single piece 1: Arrangement of multiple pieces

    Range 0, 1 · Takes effect: At power on

  2. bit 1

    Automatic setting of the material model for a MAZATROL program of initial-point scheme on the VIRTUAL MACHINING or 3D MONITOR display

    Automatic setting of the material model for a MAZATROL program of initial-point scheme on the VIRTUAL MACHINING or 3D MONITOR display. 0: Valid 1: Invalid

    Range 0, 1 · Takes effect: At power on

  3. bit 2

    When assigning G-code for a cutting function not to be represented with the INTELLIGENT SAFETY SHIELD being selected for automatic operation, operation is continued/alarm state

    Machine status when assigning G-code for a cutting function not to be represented with the INTELLIGENT SAFETY SHIELD being selected for automatic operation. 0: Continuing the operation by canceling the interference check function for material model 1: Alarm stop

    Range 0, 1 · Takes effect: At power on

  4. bit 3

    When a program prepared and stored for the Hard Disk operation is called up as a subprogram with the INTELLIGENT SAFETY SHIELD being selected for automatic operation, operation is continued/alarm state

    Machine status when a program prepared and stored for the Hard Disk operation is called up as a subprogram with the INTELLIGENT SAFETY SHIELD being selected for automatic operation. 0: Continuing the operation by canceling the INTELLIGENT SAFETY SHIELD for automatic operation 1: Alarm stop [Related parameters] F37 bit 5

    Range 0, 1 · Takes effect: At power on

  5. bit 4

    Representation of cutting-off or parting operation on the VIRTUAL MACHINING and 3D MONITOR displays

    Representation of cutting-off or parting operation on the VIRTUAL MACHINING and 3D MONITOR displays 0: No representation (Cut-off part remains shown in its original place and undergoes the interference check.) 1: Representation (Cut-off part is hidden and excluded from the interference check.)

    Range 0, 1 · Takes effect: Immediate

  6. bit 5

    Movement of traction tailstock or carriage-connection steadyrest during zero-point return operation of all axes on the VIRTUAL MACHINING display

    Traction tailstock or traction work rest operation when [ALL AXIS ZERO RET] is selected on the VIRTUAL MACHINING display 0: Zero-point return 1: No zero-point return

    Range 0, 1 · Takes effect: Immediate

  7. bit 7

    Alarming/No alaming when the feed-overriding value has been changed in the flow of automatic operation with the INTELLIGENT SAFETY SHIELD being active

    Select whether or not it is to be indicated by an alarm message that the feed-overriding value has been changed in the flow of automatic operation with the INTELLIGENT SAFETY SHIELD being active. 0: Alarming 1: No alarming

    Range 0, 1 · Takes effect: Immediate

Source

Mazak PARAMETER LIST / ALARM LIST / M-CODE LIST, manual HA64HA0035E, p. 29, 182, 183, 184. Reference and explanation only — not a reproduction of the manual.