PARAMUser parameter · EIA/ISO (F)
F41

Threading termination waiting time processing

Machine-specific. This parameter list is specific to the Mazak INTEGREX e-670H / e-670H-S with the MAZATROL SmoothX control (manual HA64HA0035E). Other Mazak models and control generations use different addresses, ranges and meanings — verify on your own control before changing anything.
What it does

Threading termination waiting time processing

Set a threading termination waiting time. F41 = 0 No waiting time F41 = 1 to 255 Setting × 1.7 ms X-axis Note : An excessively high setting may cause the thread of the run-out section to be destroyed.

Setting
Setting range0 to 255
Unit1.7 ms
Program typeM
Takes effectImmediate
Source

Mazak PARAMETER LIST / ALARM LIST / M-CODE LIST, manual HA64HA0035E, p. 30, 190. Reference and explanation only — not a reproduction of the manual.

Not sure what to set? Ask the Mazatrol assistant →