PARAMUser parameter · EIA/ISO (F)
F42
Deceleration area r during Z-axis measurement
Machine-specific. This parameter list is specific to the Mazak INTEGREX e-670H / e-670H-S with the MAZATROL SmoothX control (manual HA64HA0035E). Other Mazak models and control generations use different addresses, ranges and meanings — verify on your own control before changing anything.
What it does
Deceleration area r during Z-axis measurement
Distance (r) between the starting point of movement at measuring speed and the measuring point This data is used when argument R is omitted in G37 command format. G37 Z_ Rr D_ F_; (G37)
Setting
Setting range0 to 99999999
Unit0.001 mm/0.0001 in
Program typeE
Takes effectAfter stop of movement
Source