PARAMUser parameter · EIA/ISO (F)
F80
EIA/ISO bit settings (8 bits)
Machine-specific. This parameter list is specific to the Mazak INTEGREX e-670H / e-670H-S with the MAZATROL SmoothX control (manual HA64HA0035E). Other Mazak models and control generations use different addresses, ranges and meanings — verify on your own control before changing anything.
Bit settings — F80 is set bit by bit
- bit 0
MAZATROL function valid/invalid
- bit 1
Automatic display of the navigation window on the occurrence of an alarm valid/invalid
- bit 2
MAINTENANCE CHECK display at power on, displayed/not displayed
- bit 3
Third page of the MAINTENANCE CHECK display, displayed/not displayed
- bit 4
GRAPHIC MAINTENANCE display on the occurrence of an alarm, displayed/not displayed
- bit 5
Learning of cutting conditions valid/invalid
- bit 6
Editing on the CUTTING CONDITION LEARN display valid/invalid
- bit 7
Destination of spare tool correction by the workpiece measurement
Source
Mazak PARAMETER LIST / ALARM LIST / M-CODE LIST, manual HA64HA0035E, p. 31, 195. Reference and explanation only — not a reproduction of the manual.