F82
EIA/ISO bit settings (8 bits)
Machine-specific. This parameter list is specific to the Mazak INTEGREX e-670H / e-670H-S with the MAZATROL SmoothX control (manual HA64HA0035E). Other Mazak models and control generations use different addresses, ranges and meanings — verify on your own control before changing anything.
Bit settings — F82 is set bit by bit
- bit 0
Characteristics estimation result graph, displayed/not displayed
- bit 1
Selection of inch/metric representation in POSITION display, TOOL DATA display, and TOOL OFFSET display modes valid/invalid
- bit 2
Basis for tool life judgment
- bit 3
—
- bit 4
X-axis diameter display on the POSITION display valid/invalid
- bit 5
—
- bit 6
Automatic setting of the grooving tool length
- bit 7
Index tool wear correction setup during automatic operation
Source
Mazak PARAMETER LIST / ALARM LIST / M-CODE LIST, manual HA64HA0035E, p. 32, 196. Reference and explanation only — not a reproduction of the manual.